Primorskaya TPP
100% of equipment for 3 boiler plants (fuel - coal) was designed and delivered. Comprehensive testing completed.
Comprehensive testing completed.Total power - 195 MW
Фото предоставлено https://kaliningradenergy.ru/
Years of implementation: 2016 - 2019, commissioning - 2020
Types of work: complete delivery of three E-240-13.8-560 KT steam boilers complete with auxiliary equipment.
The main parameters of equipment: vertical water tube boiler, single drum, made with a closed A-shaped layout, with natural circulation, suspended type, gas-tight, designed to operate on a balanced draft and with solid ash removal.
Steam capacity – 240 t/h
Steam outlet temperature - 560°С
Steam outlet pressure - 13.8 MPa